Showing
of 854
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
CR4510-250,CR4510-500
CR4510-250
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
26
In Stock
1 : 194,00000 €
Box
Box
ActiveTrue RMS AC Voltage Transducer0 ~ 250VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock V-1C
ISOBLOCK V-1C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
146
In Stock
1 : 266,04000 €
Box
Box
ActiveVoltage Transducer±1000V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CLB-120-ALE-5
CLB-120-ALE-5
THREE PHASE CURRENT UNBALANCE AN
Mueller Electric Co
30
In Stock
1
Factory
1 : 363,62000 €
Box
Box
ActiveCurrent Transducer-10A-100ms-120VACChassis MountScrew Terminal0°C ~ 55°C-
IsoBlock V-1C
ISOBLOCK V-1C (1000V 5V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
13
In Stock
1 : 266,04000 €
Box
Box
ActiveVoltage Transducer±1000V±5V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
12
In Stock
1 : 266,04000 €
Box
Box
ActiveVoltage Transducer±1500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (500V 10V)
TRANSDUCER VOLTAGE 8-28VDC
Verivolt LLC
8
In Stock
1 : 298,84000 €
Box
Box
ActiveVoltage Transducer±500V±10V1500V (Working)2.8µs±0.2%8 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2308027
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
9
In Stock
1 : 345,49000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
IsoBlock I-FG-4C
ISOBLOCK I-FG-4C (25A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
2
In Stock
1 : 666,63000 €
Box
Box
ActiveCurrent Transducer0 ~ 25A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
4
In Stock
1 : 890,21000 €
Box
Box
ActiveVoltage Transducer±500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (1000V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
1
In Stock
1 : 890,21000 €
Box
Box
ActiveVoltage Transducer±1000V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (1500V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
2
In Stock
1 : 890,21000 €
Box
Box
ActiveVoltage Transducer±1500V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-4C
ISOBLOCK V-4C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
3
In Stock
1 : 999,96000 €
Box
Box
ActiveVoltage Transducer±300V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
CR4620,CR4510,CR4810,CR4820 Parts
CR4620-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
4
In Stock
This product has a maximum purchase limit
1 : 112,74000 €
Box
Box
ActiveAverage RMS AC Voltage Transducer0 ~ 150VAC4 ~ 20mA2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
CR4510-50
CR4510-150
TRANSDUCER VOLTAGE 24VDC
CR Magnetics Inc.
4
In Stock
1 : 194,00000 €
Bulk
Bulk
ActiveTrue RMS AC Voltage Transducer0 ~ 150VAC0 ~ 5VDC2500VDC250ms0.5%24VDCDIN RailScrew Terminal0°C ~ 60°CCE, cURus
IsoBlock I-FG-1C
ISOBLOCK I-FG-1C (15A 10V)
TRANSDUCER CURRENT 9-28VDC
Verivolt LLC
11
In Stock
1 : 189,65000 €
Box
Box
ActiveCurrent Transducer0 ~ 15A±10V1200V (Working)5µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2813486
2813486
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
4
In Stock
31
Factory
1 : 333,06000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2308027
2308108
TRANSDUCER CURRENT 24VDC
Phoenix Contact
11
In Stock
1 : 337,51000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A0 ~ 10VDC300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
IsoBlock V-1C
ISOBLOCK V-1C (50V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
2
In Stock
1 : 266,04000 €
Box
Box
ActiveVoltage Transducer±50V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (300V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
4
In Stock
1 : 298,84000 €
Box
Box
ActiveVoltage Transducer±300V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
IsoBlock V-1C
ISOBLOCK V-1C (750V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
3
In Stock
This product has a maximum purchase limit
1 : 298,84000 €
Box
Box
ActiveVoltage Transducer±750V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
2308027
2308030
TRANSDUCER CURRENT 24VDC
Phoenix Contact
13
In Stock
1 : 350,93000 €
Bulk
Bulk
ActiveCurrent Transducer0 ~ 200A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
IsoBlock V-4C
ISOBLOCK V-4C (100V 10V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
18
In Stock
1 : 890,21000 €
Box
Box
ActiveVoltage Transducer±100V±10V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
ENTUBE SE
ENTUBE SE (1000V 10V)
TRANSDUCER VOLTAGE DIVIDER
Verivolt LLC
2
In Stock
This product has a maximum purchase limit
1 : 206,88000 €
Box
Box
ActiveVoltage Transducer±1000V±10V--±0.2%-DIN RailSpring Terminal-25°C ~ 70°C-
E83-2050
E83-2050
TRANSDUCER CURRENT 10-40VDC
Carlo Gavazzi Inc.
18
In Stock
1 : 258,13000 €
Bag
Bag
ActiveCurrent Transducer0 ~ 50A4 ~ 20mA-200ms±2%10 ~ 40VDCDIN RailScrew Terminal-20°C ~ 50°CCE, UL
IsoBlock V-1C
ISOBLOCK V-1C (500V 5V)
TRANSDUCER VOLTAGE 9-28VDC
Verivolt LLC
2
In Stock
1 : 266,04000 €
Box
Box
ActiveVoltage Transducer±500V±5V1500V (Working)2.8µs±0.2%9 ~ 28VDCDIN RailSpring Terminal-25°C ~ 70°C-
Showing
of 854

Monitor - Current/Voltage Transducer


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.